Clausius-Clapeyron Calculator

Pressure, temperature or heat from two points.

  • Solve any one unknown
  • Kelvin enforced
  • Numerical cross-check
A small rounded clay table with a soft clay pot on a rounded stand, soft clay puffs of steam rising in a curve, and a few loose rounded beads.

The guide

Boiling is a pressure test, and the Clausius-Clapeyron equation says how the temperature must move

Why vapour pressure plotted against 1/T is a straight line, what that line assumes about the heat and the vapour, and how two measured points give a latent heat.

  • 70.6298 kPa P at 363.15 K from 101.325 kPa at 373.15 K, L 40.66 kJ/mol
  • 93.39 degrees C boiling point of that liquid at 80 kPa
  • 41508 J/mol heat from 101.325 kPa at 373.15 K and 70.1 kPa at 363.15 K
  • 0.4425 kPa the wrong answer when degrees C go into the 1/T terms
  • -4890 K slope of ln P against 1/T for L = 40.66 kJ/mol
Read the full guide Fold the guide 6 min · 16 sources

A kettle on a mountain boils at a lower temperature than the same kettle at the coast, and the water is no less water. What changed is the air above it. A liquid boils when its vapour pressure equals the pressure around it, so a boiling point is a reading of two things at once: the liquid, and the pressure it sits in.

That makes the curve of vapour pressure against temperature the more useful object. Every point on it is a boiling point for some surrounding pressure. The Clausius-Clapeyron relation describes how steeply that curve climbs, and it does so with one number per liquid, the heat needed to turn a mole of liquid into vapour.

Where the relation comes from

Start with the exact statement, the Clapeyron relation. Along the line where two phases coexist on a pressure-temperature diagram, the slope of the tangent is dP/dT = L / (T times the change in molar volume). Here L is the molar latent heat, the enthalpy absorbed per mole in the change of phase. Nothing in it is specific to one substance, but it needs the volume change as well as the heat. Clapeyron reached it by following a Carnot cycle on saturated steam. About thirty years later Clausius determined the form of the temperature function, which is why both names stay on the equation.

Two approximations turn it into something a person can use with a pencil. Well below the critical temperature the gas takes far more room than the liquid, so the volume change is nearly the gas volume alone. And if the pressure is low, the gas follows the ideal gas law and occupies R T / P per mole. Substitute both and the volume drops out: dP/dT = L P / (R T squared).

That is the Clausius-Clapeyron equation. It asks for no volume data at all, only L, the gas constant R and the temperature.

Why 1/T straightens the curve

Divide both sides by P and you get dP / P = (L / R) dT / T squared. The left side integrates to a logarithm. The right side integrates to minus 1/T, once L is held constant. Between two points the result is ln(P2 / P1) = -(L / R)(1/T2 - 1/T1).

Read that as the equation of a line. Plot ln P upward and 1/T across, and the vapour-pressure curve, which bends sharply on ordinary axes, becomes straight with slope -L / R. That is why linear regression on ln P against 1/T is used to estimate a latent heat from measurements. For L = 40.66 kJ/mol the slope is -4890 K, and hotter points sit to the left, because 1/T shrinks as T grows.

Here is a worked example with round numbers. Take a liquid with L = 40.66 kJ/mol that boils at 101.325 kPa and 373.15 K, and cool it to 363.15 K. The reciprocal temperatures are 0.00267989 and 0.00275368 per kelvin, so 1/T2 minus 1/T1 is 7.3796e-5. Multiply by L / R, which is 4890.27 K, and flip the sign: the exponent is -0.36088. The ratio is 0.69706, and the new pressure is 70.6298 kPa.

The gas constant in that sum is the exact SI value, 8.314462618 and a few more digits in J/(mol K), the product of the Avogadro and Boltzmann constants. NIST lists it as exact. The Wikipedia worked example for water uses the rounded 8.31 with 40.7 kJ/mol and 1 bar at 373 K, and that formula gives 0.6224 bar at 360 K. The two versions of R differ by about 0.05 percent, which is a fair measure of how much the rounding matters.

Three slips ruin this calculation more often than any mathematical subtlety. Put degrees Celsius into the 1/T terms, 100 and 90 instead of 373.15 and 363.15, and the same sum returns 0.4425 kPa, wrong by a factor of about 160. Pass L in kilojoules per mole next to R in joules and it returns 101.29 kPa, as if the liquid had not cooled at all. Flip the sign and the pressure climbs as the liquid cools.

Units for pressure are a lesser trap, because only the ratio P2 / P1 enters the exponent. A bar is exactly 100000 Pa, a standard atmosphere exactly 101325 Pa, and a millimetre of mercury is 133.322387415 Pa by its current definition. Temperature must be absolute. Celsius adds 273.15, and Fahrenheit adds 459.67 before dividing by 1.8.

What the two assumptions cost

A constant L is the larger approximation. The enthalpy of vaporization depends on temperature: it shrinks as the liquid warms and vanishes at the critical temperature, where liquid and vapour become one fluid. A constant value is reasonable over small temperature ranges and well below the critical temperature. Water’s critical point is 647.096 K and 22,060 kPa, so water at 373.15 K sits at 0.58 of its critical temperature, comfortable but not negligible.

The ideal vapour is the other half, and it is a better picture near atmospheric pressure than far above it. A pressure cooker gives a test. Wikipedia tabulates 121 degrees C for a gauge pressure of 1.0 bar above the sea-level atmosphere. Treat that as 201325 Pa absolute with L = 40.66 kJ/mol, and the formula gives 120.6 degrees C. A drift of 0.4 degrees over a rise of about twenty is the price of both assumptions together, and the table itself is rounded to a whole degree.

Even the heat is a choice. Wikipedia’s table of enthalpies lists 40.66 kJ/mol for water at its normal boiling point, its text gives 40.65, and the worked example in the relation’s own article uses 40.7. These are one measured quantity quoted three ways, and the choice moves the pressure at 363.15 K by less than 0.04 percent.

Why water boils cooler on a mountain

Boiling happens when the vapour pressure reaches the pressure outside, so the question on a mountain is only what the outside pressure is. NASA Glenn gives a fit for the troposphere. The temperature in degrees Celsius is 15.04 minus 0.00649 times the height in metres, and the pressure in kilopascals is 101.29 times ((T + 273.1) / 288.08) to the power 5.256. At 2000 m that gives 79.6 kPa.

Now solve the equation for T2 instead of P2. With the same liquid and a reference point of 101.325 kPa at 373.15 K, a pressure of 80 kPa boils at 366.54 K, which is 93.39 degrees C. At 79.58 kPa, the NASA figure for 2000 m, the answer is 93.25 degrees C. Wikipedia’s boiling-point table for water lists 93.4 degrees C at 2000 m. A gap of 0.15 degrees from a two-parameter formula is small.

The inverse form has a ceiling. As T grows without limit, 1/T tends to zero and P tends to P1 times e to the power L / (R T1). Ask for a pressure above that and there is no temperature to give, so the tool says so instead of printing a number. For this liquid the ceiling lies far beyond anything the real liquid reaches before its critical point.

Two points give a heat, and what is left out

Run the algebra the other way and two measured points give the heat: L = R ln(P2 / P1) / (1/T1 - 1/T2). With 101.325 kPa at 373.15 K and 70.1 kPa at 363.15 K the heat is 41508 J/mol, which is 2.1 percent above the 40660 used earlier.

The excess is not a flaw in the equation. Ten kelvin is a short baseline, and a short baseline magnifies any slip in a pressure. A one percent error in 70.1 kPa moves the heat by about 1100 J/mol, or 2.8 percent. Points spaced further apart, or a regression through many points, tame that.

What the equation does not cover is stated on the page as well. It uses no specific volumes, so it cannot give the full Clapeyron slope near the critical point. It does not let L change with temperature. It says nothing about solid-vapour or solid-liquid transitions, solutions, mixtures or humid air.

Every answer on the page is checked by integrating dP/dT = L P / (R T squared) with an adaptive Dormand-Prince scheme, an embedded Runge-Kutta pair that estimates its own error and sizes each step from it. For the first example the integration returns 70.6298 kPa and agrees with the closed form to better than one part in a trillion. The numbers are printed with Intl.NumberFormat, and the integration runs in a Web Worker so that typing never stalls.

Boiling, in the end, is a negotiation between two pressures, and the equation is the exchange rate: for each step in reciprocal temperature a liquid’s pressure moves by a factor set by one number, its heat. Keep temperatures absolute, keep the units paired, and the line stays straight.

Sources

Every source consulted for this guide. Links checked November 11, 2026.

  1. Clausius-Clapeyron relation Wikipedia (CC BY-SA)
  2. Vapor pressure Wikipedia (CC BY-SA)
  3. Enthalpy of vaporization Wikipedia (CC BY-SA)
  4. Boiling point Wikipedia (CC BY-SA)
  5. Pressure cooker Wikipedia (CC BY-SA)
  6. Critical point (thermodynamics) Wikipedia (CC BY-SA)
  7. Standard atmosphere (unit) Wikipedia (CC BY-SA)
  8. Millimetre of mercury Wikipedia (CC BY-SA)
  9. Bar (unit) Wikipedia (CC BY-SA)
  10. Celsius Wikipedia (CC BY-SA)
  11. Fahrenheit Wikipedia (CC BY-SA)
  12. Dormand-Prince method Wikipedia (CC BY-SA)
  13. Earth Atmosphere Model - Metric Units NASA Glenn Research Center
  14. CODATA Value: molar gas constant National Institute of Standards and Technology
  15. Web Workers API - Web APIs MDN Web Docs (CC BY-SA)
  16. Intl.NumberFormat - JavaScript MDN Web Docs (CC BY-SA)